<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CSA Series Limit Switches &#8211; Weiller Elektrik</title>
	<atom:link href="https://www.weiller.com.tr/category/products/limit-switch/csa-series-limit-switches/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.weiller.com.tr</link>
	<description></description>
	<lastBuildDate>Sat, 14 Nov 2020 08:31:32 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>CS-081 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/cs-081-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/cs-081-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:59:52 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[wobble]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4565</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-medium wp-image-4568" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-081-80x300.jpg" alt="" width="80" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-081-80x300.jpg 80w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-081-272x1024.jpg 272w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-081.jpg 560w" sizes="(max-width: 80px) 100vw, 80px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Spring Wobble</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div>

			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		</div>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/cs-081-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-071 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-071-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-071-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:55:59 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[plastic]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[end]]></category>
		<category><![CDATA[wobble]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4561</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-medium wp-image-4562" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-071-78x300.jpg" alt="" width="78" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-071-78x300.jpg 78w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-071-265x1024.jpg 265w" sizes="(max-width: 78px) 100vw, 78px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Spring Wobble Plastic End</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<div></div>
<div></div>
<div>

			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		</div>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-071-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-061 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-061-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-061-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:51:59 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[spring]]></category>
		<category><![CDATA[catswhisker]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4557</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-medium wp-image-4558" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-061-81x300.jpg" alt="" width="81" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-061-81x300.jpg 81w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-061-277x1024.jpg 277w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-061.jpg 560w" sizes="(max-width: 81px) 100vw, 81px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Spring Cat&#8217;s Whisker</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div>

			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		</div>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-061-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-031 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-031-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-031-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:49:08 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[arm]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[adjustable]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[limit]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4553</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4554" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-031-143x300.jpg" alt="" width="143" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-031-143x300.jpg 143w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-031-488x1024.jpg 488w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-031.jpg 573w" sizes="auto, (max-width: 143px) 100vw, 143px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Adjustable Metal Arm, With Metal Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div>

			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		</div>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-031-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-021 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-021-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-021-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:46:51 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[limit]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4550</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4551" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-021-153x300.jpg" alt="" width="153" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-021-153x300.jpg 153w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-021-524x1024.jpg 524w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-021.jpg 584w" sizes="auto, (max-width: 153px) 100vw, 153px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Aplication</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:Head Type:</td>
<td>:  Snap Action:  Metal Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<div class="mainHeading"></div>
<div>
<div>

			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		</div>
<p>&nbsp;</p>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-021-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-021 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-012-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-012-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:43:14 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[snap]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[plunger]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[lift]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4545</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4546" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-012-150x300.jpg" alt="" width="150" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-012-150x300.jpg 150w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-012-512x1024.jpg 512w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-012.jpg 576w" sizes="auto, (max-width: 150px) 100vw, 150px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Metal Roller Plunger</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-012-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-003 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-003-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-003-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:40:17 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[plunger]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[metal]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4539</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4540" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-003-149x300.jpg" alt="" width="149" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-003-149x300.jpg 149w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-003-508x1024.jpg 508w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-003.jpg 552w" sizes="auto, (max-width: 149px) 100vw, 149px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Metal Roller Plunger</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-003-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CSA-001 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-001-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-001-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Sat, 02 May 2020 17:37:25 +0000</pubDate>
				<category><![CDATA[CSA Series Limit Switches]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[plunger]]></category>
		<category><![CDATA[csa]]></category>
		<category><![CDATA[lift]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4527</guid>

					<description><![CDATA[CSA Series Limit Switches Internationel Case Solid Quality Heavy Duty Aplication Technical Specifications Mechanical Life : 10.000.000 Operations Electrical Life : 500.000 Operations Operation Temperature : -10../.. +70°C Operation Voltage : 240 VAC Maximum Current (ithe) : 10A Operation Current (le) : 3A Isolated Voltage : 250V Operation Frequency (f) : 50/60 Hz Contact Material : [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4530" src="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-001-184x300.jpg" alt="" width="184" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-001-184x300.jpg 184w, https://www.weiller.com.tr/wp-content/uploads/2020/08/CSA-001.jpg 554w" sizes="auto, (max-width: 184px) 100vw, 184px" /></p>
<p><strong>CSA Series Limit Switches</strong></p>
<table style="height: 900px;" width="658">
<tbody>
<tr>
<td>Internationel Case</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Solid Quality</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Heavy Duty Aplication</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 10.000.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10../.. +70°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 10A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 3A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50/60 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Cable Diameter</td>
<td colspan="3">: 0,75mm, 1mm, 1.50mm</td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Activation Type:</p>
<p>Head Type:</td>
<td>:  Snap Action</p>
<p>:  Metal Plunger</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong>Description</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Metal Body</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Ergonomic Design</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Multiple options for head types</td>
<td></td>
</tr>
<tr>
<td colspan="2">High mechanical durability</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">PG-13.5 or M20x1.5 Cable Gland Connection</td>
<td></td>
<td></td>
</tr>
<tr>
<td>M3 Terminals</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="5">Easy install</td>
</tr>
<tr>
<td>Multiple gaskets for better protection</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/csa-series-limit-switches/csa-001-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
