<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CWL Series Limit Switches &#8211; Weiller Elektrik</title>
	<atom:link href="https://www.weiller.com.tr/category/products/limit-switch/cwl-series-limit-switches/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.weiller.com.tr</link>
	<description></description>
	<lastBuildDate>Sat, 14 Nov 2020 08:39:53 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>
	<item>
		<title>CWLD3 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld3-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld3-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Thu, 03 Sep 2020 13:40:39 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[ıp66]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[limit]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4677</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-medium wp-image-4678" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD3-126x300.jpg" alt="" width="126" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD3-126x300.jpg 126w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD3.jpg 300w" sizes="(max-width: 126px) 100vw, 126px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Metal Piston Pim</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-medium wp-image-4686" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWDL3-Şema-AEK-1-300x267.jpg" alt="" width="300" height="267" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWDL3-Şema-AEK-1-300x267.jpg 300w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWDL3-Şema-AEK-1.jpg 325w" sizes="(max-width: 300px) 100vw, 300px" /></p>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld3-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLD Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:22:14 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[plunger]]></category>
		<category><![CDATA[CWD]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[case]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4653</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img decoding="async" class="alignnone size-medium wp-image-4650" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD-136x300.jpg" alt="" width="136" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD-136x300.jpg 136w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD.jpg 300w" sizes="(max-width: 136px) 100vw, 136px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Metal Plunger</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4655" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD-ŞEMA-300x263-AEK-300x263.png" alt="" width="300" height="263" /></p>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLD2 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld2-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld2-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:17:56 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[limit]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[plunger]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4670</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4671" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD2-127x300.jpg" alt="" width="127" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD2-127x300.jpg 127w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLD2.jpg 300w" sizes="auto, (max-width: 127px) 100vw, 127px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Metal Plunger With Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-4672" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWDL2-ŞEMA-AEK.jpg" alt="" width="291" height="268" /></p>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwld2-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLCA2-2 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca2-2-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca2-2-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:15:27 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[roller]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[spring]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[cover]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[case]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[ıp66]]></category>
		<category><![CDATA[limit]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[metalroller]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[lift]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4690</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4691" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA2-2-111x300.jpg" alt="" width="111" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA2-2-111x300.jpg 111w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA2-2.jpg 300w" sizes="auto, (max-width: 111px) 100vw, 111px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: 18mm Metal Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-4692" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA2-2-AEK.jpg" alt="" width="295" height="298" /></p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca2-2-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLCA12-2Q Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca12-2q-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca12-2q-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:13:22 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[arm]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[plasticroller]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[adjustable]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[metalroller]]></category>
		<category><![CDATA[safetyschalter]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[straight]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[roller]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4701</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 Hz [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4702" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLC12-2Q-119x300.jpg" alt="" width="119" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLC12-2Q-119x300.jpg 119w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLC12-2Q.jpg 300w" sizes="auto, (max-width: 119px) 100vw, 119px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Adjustable Straight Arm With Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4703" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA12-2Q-300x288.png" alt="" width="300" height="288" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA12-2Q-300x288.png 300w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA12-2Q.png 309w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca12-2q-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLCA32-41 Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca32-41-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca32-41-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:11:52 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[palsticroller]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[case]]></category>
		<category><![CDATA[limit]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[cwl]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[position]]></category>
		<category><![CDATA[arm]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[plasticroller]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4709</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 Hz [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4710" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA32-41-173x300.jpg" alt="" width="173" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA32-41-173x300.jpg 173w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCA32-41.jpg 300w" sizes="auto, (max-width: 173px) 100vw, 173px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Double Plastic Roller</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4717" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLA32-41-ŞEMA-AEK-2-300x293.png" alt="" width="300" height="293" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLA32-41-ŞEMA-AEK-2-300x293.png 300w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLA32-41-ŞEMA-AEK-2.png 312w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>
<p>&nbsp;</p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlca32-41-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLC-CL Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlc-cl-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlc-cl-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 10:08:40 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[ıp66]]></category>
		<category><![CDATA[cwl]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[lift]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[adjustable]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[rod]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4733</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4734" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL-92x300.jpg" alt="" width="92" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL-92x300.jpg 92w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL.jpg 300w" sizes="auto, (max-width: 92px) 100vw, 92px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Adjustable Metal Rod</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></p>
<p>&nbsp;</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4735" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL-ŞEMA-AEK-300x285.png" alt="" width="300" height="285" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL-ŞEMA-AEK-300x285.png 300w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLCL-ŞEMA-AEK.png 521w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlc-cl-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>CWLNJ Limit Switch 1NO+1NC</title>
		<link>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlnj-30-limit-switch-1no1nc/</link>
					<comments>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlnj-30-limit-switch-1no1nc/#respond</comments>
		
		<dc:creator><![CDATA[emin]]></dc:creator>
		<pubDate>Fri, 20 Mar 2020 09:59:47 +0000</pubDate>
				<category><![CDATA[CWL Series Limit Switches]]></category>
		<category><![CDATA[positionswitch]]></category>
		<category><![CDATA[switch]]></category>
		<category><![CDATA[positionschalter]]></category>
		<category><![CDATA[snapaction]]></category>
		<category><![CDATA[metal]]></category>
		<category><![CDATA[weiller]]></category>
		<category><![CDATA[spring]]></category>
		<category><![CDATA[wobble]]></category>
		<category><![CDATA[rod]]></category>
		<category><![CDATA[limitswitch]]></category>
		<category><![CDATA[safetyswitch]]></category>
		<category><![CDATA[lift]]></category>
		<guid isPermaLink="false">https://www.weiller.com.tr/?p=4720</guid>

					<description><![CDATA[CWL Series Limit Switch  Internationel Metal Case Solid Quality Heavy Duty Applications &#160; Technical Specifications Mechanical Life : 15.000.000 Operations (120/1Minute) Electrical Life : 500.000 Operations(30/1Minute) Operation Temperature : -10/.. +80°C Operation Voltage (Ue) : 240 VAC Maximum Current (ithe) : 20A Operation Current (le) : 15A Isolated Voltage : 250V Operation Frequency (f) : 50 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4721" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ-77x300.jpg" alt="" width="77" height="300" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ-77x300.jpg 77w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ.jpg 250w" sizes="auto, (max-width: 77px) 100vw, 77px" /></p>
<p><strong>CWL Series Limit Switch </strong></p>
<table width="658">
<tbody>
<tr>
<td><strong><em>Internationel Metal Case</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"><strong><em>Solid Quality</em></strong></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong><em>Heavy Duty Applications</em></strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>&nbsp;</p>
<p><strong>Technical Specifications</strong></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Mechanical Life</td>
<td colspan="3">: 15.000.000 Operations (120/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Electrical Life</td>
<td colspan="3">: 500.000 Operations(30/1Minute)</td>
<td></td>
</tr>
<tr>
<td>Operation Temperature</td>
<td colspan="2">: -10/.. +80°C</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Voltage (Ue)</td>
<td colspan="2">: 240 VAC</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Maximum Current (ithe)</td>
<td>: 20A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Current (le)</td>
<td>: 15A</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Isolated Voltage</td>
<td>: 250V</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Frequency (f)</td>
<td>: 50 Hz</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Contact Material</td>
<td>: Ag/Cu</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Utilization Category</td>
<td>: AC15</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Protection</td>
<td>: IP66 (IEC)</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Operation Humidty</td>
<td colspan="3">: &lt;% 95</td>
<td></td>
</tr>
<tr>
<td>Standart</td>
<td colspan="2">: EN 60947-5-1</td>
<td></td>
<td></td>
</tr>
<tr>
<td>Certification</td>
<td>: CE</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Insulation Resistance</p>
<p>Contact Resistance</p>
<p>Activation Type:</p>
<p>Head Type:</td>
<td>: 100MΩ    500Vdc</p>
<p>: 15MΩ</p>
<p>: Snap Action</p>
<p>: Metal Spring Wobble</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">&nbsp;</p>
<p><strong>Description:</strong></p>
<p>&nbsp;</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Double-Circuit type, 1NO+1NC Contact Option</td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">Multiple options for head types</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="4">Indicating plate with setting poisiton is installed in it, so it is easy to maintain</td>
<td></td>
</tr>
<tr>
<td colspan="2">Strong aliminum cast outer shell</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2">With M20x1.5 Cable gland connector</td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="3">High Sensitivity, Long Durability.</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Dimensions;</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4722" src="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ-ŞEMA-AEK-300x278.jpg" alt="" width="300" height="278" srcset="https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ-ŞEMA-AEK-300x278.jpg 300w, https://www.weiller.com.tr/wp-content/uploads/2020/09/CWLNJ-ŞEMA-AEK.jpg 323w" sizes="auto, (max-width: 300px) 100vw, 300px" /></p>


			<div class="mainHeading">
				<div class="icon iletisim"></div>
				<div class="title">For further information, info@weiller.com</div>
			</div>

		
]]></content:encoded>
					
					<wfw:commentRss>https://www.weiller.com.tr/products/limit-switch/cwl-series-limit-switches/cwlnj-30-limit-switch-1no1nc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
